E44-865 · Throttling Noise and Vibration · Pipe downstream of throttling · ★★
Insufficient straight pipe downstream of the throttling valve gave Re=3×10⁶ vortex shedding noise of 90dB(A)
[Mechanism] The high-speed flow after throttling forms large-scale vortex shedding that is released periodically, and the vortex shedding noise rises with Reynolds number and velocity.
[Calculation] Strouhal number St=0.2, vortex frequency f=St·v/d, Re=vd/ν=3×10⁶ enters strong turbulence.
[Design Omission] No flow stabilization, no long straight pipe, no silencing.
1) Stabilize the flow to cut vortex shedding (add a straightener downstream of the valve + a long straight pipe to even the flow field), since the original Re3e6 vortex shedding gave 90dB(A), thus stabilizing cuts the noise;
2) Verify Re is moderate (limit the velocity to bring Re down into the steady turbulence region), since a large value sheds and verification controls it, thus verifying Re;
3) Lengthen the straight pipe (≥10D downstream of the valve), since short sheds and long dissipates, thus lengthening;
4) Add a silencer (resistive, insertion loss ≥10dB), since the bare pipe radiates 90dB(A) and silencing lowers it, thus silencing;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the velocity to steady it (limit v), since changing conditions drift the vortex frequency and steadying controls it, thus controlling speed;
8) Write the flow stabilization and lengthening into the specification, since the original lack of stabilization is the root cause of vortices and locking it in closes the loop, thus controlling it in the spec.
GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure