E44-711 · Hydraulic System Contamination and Crawling · Oil Tank · ★★
Sediment contamination, accumulation
[Mechanism] Uncleaned sediment contaminates the oil.
[Calculation] Sediment causes contamination.
[Design Omission] No cleaning, no draining, and no inspection - a design defect leading to sediment.
1) Schedule tank cleaning to remove sediment (annual cleaning, flush clean); the original sediment recirculated and contaminated and jammed the valve, so cleaning the tank purifies the oil;
2) Provide a sediment drain outlet (bottom drain valve, weekly draining); accumulation causes contamination, so draining removes the source;
3) Magnetically remove iron swarf (magnetic bars, cleaned weekly); ferrous particles contaminate the oil, so magnetic capture removes them;
4) Filter new oil before filling (to NAS 8); new oil can carry contamination, so filtering keeps it clean;
5) Check the sediment amount (weigh when cleaning; report any quantity); gradual accumulation is invisible, so checking makes it measurable;
6) Seal the tank against dust (tight lid, flanged joints); an open tank gets contaminated, so sealing keeps dust out;
7) Schedule quarterly oil-quality inspection (visual condition); gradual contamination is invisible, so inspection catches it early for early warning;
8) Write tank cleaning and draining into the maintenance card (tank cleaning record); since lack of cleaning was the root cause of sediment, closing the loop in the maintenance card gives maintenance control.
GB/T 3766-2015 General technical conditions for hydraulic systems