E44-309 · Excessive Pipe Resistance and Pressure Drop · A straight-tee split off a DN150 main · ★★
The flow split drives the branch local-loss coefficient to ζ=1.2, hj=0.06MPa, and branch flow to only 80% of design.
[Flow Split] The tee's flow split redistributes velocities and raises local loss ζ.
[Shortfall] The heavy branch pressure loss drops the flow to 80%.
[Design Omission] No flow-through tee and no split-loss check — heavy loss at the tee.
1) Switch to a flow-through (angled) tee to cut ζ to 0.5, since a right-angle split at ζ=1.2 gives hj=0.06 and 80% flow — thus aligning flow to cut loss;
2) Check the split local loss Σζv²/2g, since omitting it starved the branch — thus accounting for all loss;
3) Enlarge the branch diameter to offset its loss, since the branch loses heavily — thus upsizing it;
4) Add branch control valves to balance, since the split is uneven — thus balancing the flow;
5) Leave a downstream straight run after the tee, since turbulence adds loss — thus calming the flow;
6) Keep pump-head margin to cover branch loss, since the branch needs pressure — thus leaving margin;
7) Arrange branches symmetrically to reduce bias flow, since bias causes imbalance — thus laying them out symmetrically;
8) Write the split loss into the design, since the unchecked loss was the root cause of the shortfall — thus locking it in at design.
GB/T 20801.3-2020 Design code for industrial metallic piping