E44-310 · Excessive Pipe Resistance and Pressure Drop · A 200-mesh Y-strainer · ★★
A 200-mesh screen gives a filter resistance Δp=0.08MPa against a 0.02 design value, cuts flow by 15%, and starves the pump suction.
[High Resistance] A fine mesh packs the screen tightly and raises local resistance.
[Flow Reduction] The excess Δp leaves the pump under-sucked.
[Design Omission] Mesh size was not matched to the fluid dirt level and no differential-pressure alarm was set — high strainer resistance.
1) Choose 80–100 mesh to match the fluid dirt level, since 200 mesh gives Δp=0.08 (over 0.02) and −15% flow — thus picking the right mesh to cut resistance;
2) Set a strainer differential-pressure alarm (clean at Δp>0.03), since rising resistance is hard to detect and starves the pump — thus cleaning early;
3) Parallel twin strainers for switchover, since a single clogged strainer shuts the line down — thus allowing switching;
4) Clean the strainer on schedule, since accumulated dirt raises resistance — thus keeping it clean;
5) Upsize the pump suction to lower v, since high velocity amplifies resistance — thus enlarging the bore;
6) Include filter resistance in the total hf, since omitting it starved the suction — thus accounting for all loss;
7) Switch to a coarser strainer when the medium is clean, since too fine a mesh serves no purpose, coarse straining;
8) Fold mesh size into selection, since the wrong mesh was the root cause of resistance — thus locking it in at design.
GB/T 20801.3-2020 Design code for industrial metallic piping