E44-162 · Seal Leakage · Pump Mechanical Seal · ★★★
The seal flush line blocked; the face temperature rose 60℃, the tribo-pair burned, and it leaked externally.
[Flush Blockage] Lost flush leaves the faces unlubricated.
[Burn] Temperature rise burns the pair and leaks.
[Design Omission] No flush filtration and no temperature monitoring — leak.
1) Fit a strainer on the seal flush line against blockage; a blocked flush line raised the face 60℃, burned the pair, and leaked externally, so filter to keep flush flowing;
2) Set flush-flow monitoring and alarm; lost flush precedes burning, so monitor flow and alarm;
3) Add a face temperature probe that alarms and trips the pump; temperature rise burns the pair, so measure temperature and stop;
4) Choose a flush liquid compatible and non-reactive with the medium; reaction damages the faces, so select the liquid;
5) Clean the flush line periodically; it gradually blocks, so clean on schedule;
6) Use a cartridge mechanical seal for easy exchange; a burned pair needs replacing, so make it cartridge and easy;
7) On trial, verify face temperature rise is within limit and no leak; design requirements need actual measurement, so confirm on delivery;
8) Bring flush assurance into mechanical seal design; the lack of assurance was the burn root cause, so the design must include it.
GB/T 14211-2019 Mechanical seals - Test methods