E44-114 · Seal Leakage · Centrifugal-Pump Stuffing Box · ★★
An over-tightened packing gland raised the sleeve temperature 120℃ and smoked; the packing carbonized and leakage was 0.5L/min.
[Overheating] An over-tight gland accumulates friction heat.
[Calculation] Excessive face pressure pushes the pv value past the packing allowable, coking and leaking.
[Design Omission] No pressure control and no leak-guiding lubrication — shaft burned.
1) Torque the gland bolts diagonally and uniformly, controlling the pressure to 3~5 drops/min leakage; over-tightening pushes pv past coking, so keep it lubricated and unburned;
2) Choose high-temperature packing (e.g., flexible graphite); graphite is heat-resistant, so resist coking;
3) Fit a lantern ring to introduce flush for cooling; lowering temperature lowers pv, so prevent overheating;
4) Make the sleeve replaceable and hardened; wear loses the shaft, so protect it;
5) Retighten the gland evenly on schedule; too loose leaks and too tight burns, so keep it moderate;
6) Set temperature monitoring and warning; temperature rise predicts shaft burning, so act early;
7) On trial, verify shaft temperature ≤60℃ and no leakage; design requirements need actual measurement, so confirm on delivery;
8) Bring the pressure spec into packing installation; over-tightening is the main cause, so hardwire prevention.
GB/T 20801.3-2020 Pressure piping code - Industrial piping - Design