Dry Gas Seal Leakage on the Centrifugal Compressor

E44-570 · Seal Leakage · Centrifugal Compressor Dry Gas Seal · ★★★

Problem Symptom

Leakage, gas film 0.2mm thick against 0.005mm, seal failure

Root Cause

[Mechanism] An unstable gas film thickness causes the seal to fail.
[Calculation] A film of 0.2mm against 0.005mm causes the seal to fail and leak.
[Design Omission] The seal gas was not controlled, not filtered and not monitored - the seal lost the film.

Correct Solution

1) Control the cleanliness of the seal gas (1 micron filter, dust <=1mg/m3); dirty particles enter and scratch the faces, breaking the gas film, so filtered gas protects the faces and preserves the film;
2) Stabilise the differential pressure at 0.3MPa above the process pressure of 0.05 (pressure regulating valve); a low differential lets process gas back-diffuse and break the film, so stabilising the pressure preserves the film;
3) Monitor the film thickness at <=0.005mm (end-face displacement); a thick film spoils the spiral groove pumping effect and leaks, so the film is monitored;
4) Verify the rotor dynamic balance (G2.5 grade); vibration makes the film thickness fluctuate and breaks it, so balancing verifies it;
5) Select a hard face pair (silicon carbide on silicon carbide); a soft face is easily scratched and breaks the film, so a hard pair is chosen;
6) Provide a differential-pressure alarm (trip below 0.05); loss of the differential causes leakage, so the alarm warns;
7) Set a routine face damage inspection (check the roughness on dismantling); damage progresses gradually and then leaks, so the face is inspected;
8) Write the gas filtration and the pressure stabilisation into the specification; the original absence of gas control was the root cause of the seal failure, so the specification closes the loop.

Checklist

References

API 617-2014 Centrifugal Compressors