E44-571 · Seal Leakage · Reactor Agitator · ★★
Leakage, wobble 0.2mm against 0.05mm, face skew
[Mechanism] A large wobble skews the sealing faces.
[Calculation] A wobble of 0.2mm against 0.05mm skews the face and the local specific pressure falls to 0, so it leaks.
[Design Omission] The shaft was never straightened, the wobble was not limited, and no suitable seal was selected - the face was skewed.
1) Verify and correct the agitator shaft straightness to <=0.05mm (straighten or replace the shaft); the original 0.2mm against 0.05mm skewed the face and the local specific pressure fell to 0 so it leaked, and straightening restores a face that meets squarely;
2) Add an intermediate bearing to limit the wobble (an additional support); a wobbling shaft skews the face, so the additional support limits it;
3) Select a double-end-face seal (better tolerance to skew); with wobble a single-face seal leaks, so a double seal is used;
4) Verify the dynamic balance (G6.3 grade) to reduce the wobble; an unbalanced rotor causes wobble, so balancing corrects it;
5) Tighten the support components to prevent shaking (reinforce the support); shaking causes wobble, so fixing the support prevents it;
6) Control the speed to avoid resonant wobble (stay away from the critical speed); vibration causes wobble, so controlling the speed prevents it;
7) Set a routine wobble inspection (dial indicator); the wobble grows gradually and then leaks, so it is measured;
8) Write the straightness and wobble limits into the specification; the original failure to straighten the shaft was the root cause of the skew, so the specification closes the loop.
GB/T 14211-2019 Technical Conditions of Mechanical Seals