E44-572 · Seal Leakage · Reactor Double-End-Face Seal · ★★★
Leakage, barrier fluid pressure lost, interface lost
[Mechanism] The barrier fluid of the double-end-face seal is lost.
[Calculation] With the barrier fluid at zero the interface is lost and the two sides cross-leak.
[Design Omission] No barrier fluid supply was provided, nothing was monitored, and the seal was not properly selected - the barrier was lost.
1) Provide a barrier fluid system holding 0.3MPa (self-contained pressure stabilisation); the original zero pressure destroyed the liquid barrier and the interface so the process gas leaked across, so supplying the fluid restores the barrier;
2) Monitor the barrier fluid level with an alarm (stop the pump on low level); cooling down loses the interface, so the level is monitored;
3) Select a compatible barrier fluid (glycerine or a compatible white oil); mixing destroys the interface, so an isolating fluid is chosen;
4) Add a check valve to prevent cross-flow (non-return); cross-flow destroys the interface, so the check valve prevents it;
5) Verify the barrier fluid flow rate at 1L/min (orifice); too little flow makes the interface unstable, so the flow is verified;
6) Control the process pressure at least 0.05 below the barrier pressure (differential pressure protection); the reverse differential causes cross-flow, so the difference is controlled;
7) Set a routine level check (every shift); the level falls gradually and the interface is lost, so the level is checked;
8) Write the barrier fluid system into the specification; the original absence of a fluid supply was the root cause of the barrier loss, so the specification closes the loop.
GB/T 14211-2019 Technical Conditions of Mechanical Seals