Barrier Fluid Contamination in a Double-End-Face Mechanical Seal

E44-573 · Seal Leakage · Double-End-Face Seal Barrier Fluid · ★★

Problem Symptom

Leakage, barrier fluid turbidity 50NTU against 10NTU, face wear

Root Cause

[Mechanism] Dirty barrier fluid wears the sealing faces.
[Calculation] A turbidity of 50NTU against 10NTU lets abrasive particles enter and damage the faces so they leak.
[Design Omission] The fluid was not filtered, not replaced and not monitored - it became contaminated.

Correct Solution

1) Add a fluid filter (5 micron, recirculating filtration); the original turbidity of 50NTU against 10NTU let abrasive particles reach the faces, scratch them and leak, so filtering the fluid protects the faces and brings the turbidity back inside 10NTU;
2) Set a barrier fluid replacement interval (3 months or online purification); the fluid dirtyens with time and abrasive particles accumulate, so replacing or purifying it keeps the fluid clean;
3) Monitor the turbidity with an alarm (alarm above 10NTU); a high turbidity causes wear, so monitoring gives early warning;
4) Select a non-contaminating fluid (white oil or a compatible grade); mixing makes the fluid dirty, so a clean fluid is chosen;
5) Clean the reservoir and remove sludge (magnetic filtration and draining); sludge raises the turbidity, so cleaning the reservoir prevents it;
6) Verify the fluid flow rate at 1L/min (pump and orifice); too little flow concentrates the contamination, so the flow is verified;
7) Set a routine turbidity check (weekly); the fluid dirties gradually and then wears the faces, so the turbidity is inspected;
8) Write the filtration and the fluid replacement into the specification; the original absence of filtration was the root cause of the contamination, so the specification closes the loop.

Checklist

References

GB/T 14211-2019 Technical Conditions of Mechanical Seals

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL