E44-574 · Seal Leakage · Dry Gas Seal Filter · ★★
Leakage, filter differential pressure 0.2MPa against 0.05MPa, gas interruption
[Mechanism] A blocked filter interrupts the seal gas supply.
[Calculation] A differential pressure of 0.2MPa against 0.05MPa stops the flow and breaks the film, so it leaks.
[Design Omission] No bypass was provided, the element was not replaced, and nothing was monitored - the filter blocked.
1) Provide a filter bypass to guarantee the gas supply (automatic switching); the blocked main filter interrupted the gas and broke the film so it leaked, and the bypass preserves the film;
2) Set a filter element replacement interval (6 months, or on the differential-pressure alarm); the filter blocks with time, so the element is replaced;
3) Monitor the differential pressure with an alarm (alarm above 0.05MPa); a high differential interrupts the supply, so the difference is monitored;
4) Improve the filter efficiency (1 micron but with a larger area); a coarse filter lets dirt through, so finer filtration protects the faces;
5) Add gas heating for dehumidification (prevent condensation blockage); moisture causes blockage and heating dehumidifies it, preventing it;
6) Verify the gas flow rate (orifice or flow meter); too little flow breaks the film, so the flow is verified;
7) Set a routine differential-pressure check (daily); the filter blocks gradually and then interrupts the supply, so the difference is checked;
8) Write the bypass and the element replacement into the specification; the original absence of a bypass was the root cause of the blockage, so the specification closes the loop.