E44-575 · Seal Leakage · Dry Gas Seal Face · ★★★
Leakage, face Ra0.2 against 0.05, gas film lost
[Mechanism] Face wear destroys the gas film.
[Calculation] Ra0.2 against 0.05 breaks the film and it leaks.
[Design Omission] The gas was not cleaned, the pressure was not controlled and nothing was inspected - the faces wore.
1) Improve the gas cleanliness (0.5 micron filter, dust <=0.1mg/m3); dirt wears the face and Ra0.2 against 0.05 breaks the film, so clean gas protects the face;
2) Stabilise the differential pressure at 0.05MPa (pressure regulating valve); a low differential breaks the film, so stabilising it preserves the film;
3) Verify the dynamic balance to reduce vibration wear (G2.5); vibration wears the face, so balancing corrects it;
4) Select a hard face pair (silicon carbide on silicon carbide); a soft face is easily scratched, so a hard pair is chosen;
5) Monitor the face temperature to prevent thermal wear (temperature transmitter); heat causes wear, so the temperature is monitored;
6) Control start-up and shutdown to prevent dry running (admit gas before rotation); dry running wears the faces, so a lubricated start prevents it;
7) Set a routine Ra inspection (check on dismantling); wear progresses gradually and then leaks, so Ra is inspected;
8) Write the gas cleanliness and the pressure stabilisation into the specification; the original absence of gas cleaning was the root cause of the wear, so the specification closes the loop.
API 617-2014 Centrifugal Compressors