E44-576 · Seal Leakage · Magnetic Fluid Seal · ★★
Leakage, magnetic induction 0.2T below rating, seal failure
[Mechanism] Demagnetisation causes the seal to fail.
[Calculation] At 0.2T against the 0.4T rating the magnetic fluid chain breaks and the seal leaks.
[Design Omission] No temperature-resistant magnet was selected, no thermal insulation was fitted and nothing was inspected - the magnets demagnetised.
1) Change to a temperature-resistant magnet (samarium-cobalt SmCo, Curie point >700C); the original ferrite magnet demagnetised above its temperature rating and the induction fell to 0.2T against 0.4T, breaking the magnetic fluid chain and leaking, so a temperature-resistant magnet preserves the magnetism;
2) Add a thermal break sleeve (water-cooled jacket); heat demagnetises the magnet and the sleeve insulates it;
3) Control the working temperature at <=200C (cooling); a high temperature demagnetises the magnet, so cooling prevents it;
4) Verify the magnetic induction at >=0.4T (gaussmeter); a low induction breaks the seal, so the induction is verified;
5) Prevent vibration-induced demagnetisation (vibration isolation mounts); vibration demagnetises and the mounts prevent it;
6) Select a stable magnetic circuit (a short-circuit ring design); an unstable circuit demagnetises, so a stable circuit is chosen;
7) Set a routine magnetic strength inspection (each maintenance shutdown); the strength fades gradually and then leaks, so it is inspected;
8) Write the temperature-resistant magnet into the specification; the original failure to select the material was the root cause of the demagnetisation, so the specification closes the loop.
GB/T 13871.1-2007 Rubber Sealing Elements