E44-569 · Seal Leakage · Centrifugal Pump Mechanical Seal · ★★
Leakage, shaft axial movement 0.5mm against 0.1mm, faces separated
[Mechanism] Large shaft axial movement separates the sealing faces.
[Calculation] Movement of 0.5mm against 0.1mm opens a 0.3mm face gap and the seal leaks.
[Design Omission] The axial movement was not limited, the shaft was not fixed, and no suitable seal was selected - the shaft moved.
1) Add a bearing lock to limit the axial movement to <=0.1mm (lock nut plus locking washer); the original 0.5mm against 0.1mm opened a 0.3mm gap that broke the liquid film and leaked, so limiting the movement brings the faces back together;
2) Tighten the shaft nut against movement (locking washer); a loose nut lets the shaft move, so fixing the shaft stops it;
3) Select a movement-tolerant seal (a cartridge type with an internal limit); movement separates the faces, so such a seal is chosen;
4) Verify the bearing clearance at <=0.05mm (replace the bearing); a large clearance permits axial movement, so the clearance is verified;
5) Add a thrust collar (axial location); movement separates the faces, so the thrust ring locates the shaft;
6) Control the shaft temperature to prevent thermal growth and movement (cooling); thermal expansion moves the shaft, so controlling the temperature prevents it;
7) Set a routine axial movement inspection (dial indicator); the movement grows gradually and then leaks, so it is measured;
8) Write the movement limit into the specification; the original absence of a movement limit was the root cause of the shaft movement, so the specification closes the loop.
GB/T 14211-2019 Technical Conditions of Mechanical Seals