E44-543 · Heat Exchanger Fouling and Insufficient Heat Exchange · Tubular Asphalt Heat Exchanger · ★★

Problem Description

High-temperature asphalt coking, blockage, reduced flow, uneven temperature

Root Cause

[Mechanism] Local overheating causes coking on the surface.
[Calculation] Excessive wall temperature causes coking, 30% blockage, uneven temperature, and reduced flow.
[Design Omission] Wall temperature was not controlled and no cleaning was done, so coking occurred.

Corrective Solution

1) Keep wall temperature below the coking threshold (wall temperature ≤320℃); because heavy asphalt components polycondense and coke when the wall temperature exceeds the thermal-cracking point, reducing flow area by 30% and creating inlet-outlet temperature unevenness, holding wall temperature below the coking point suppresses coking and preserves rated flow;
2) Schedule mechanical decoking (every 2000 operating hours); because the coke layer adheres strongly once cured and online hydraulic cleaning cannot remove it, periodic mechanical decoking restores flow area and heat transfer;
3) Add online inlet-outlet differential-pressure monitoring (alarm at Δp>0.1MPa); because coking reduces flow area and differential pressure rises before flow drops, it gives early warning of blockage and avoids sudden shutdown;
4) Raise flow velocity to the design upper limit (≥1.5m/s) to prevent stagnation; because low-velocity zones have long residence time and rising wall temperature that promotes coking, higher velocity reduces residence time and suppresses coking;
5) Distribute heat uniformly on the heating side (switch to spiral baffles / zoned temperature control); because local hot spots are the source of coking and uneven heating worsens flow maldistribution, uniform heating eliminates hot spots;
6) Switch tubes to heat-resistant steel (316L / aluminized); because ordinary carbon steel has a low temperature limit and long-term over-temperature causes oxide scaling that promotes coking, heat-resistant material extends life and suppresses coking;
7) Inspect coke thickness on schedule (infrared wall-temperature measurement / borescope quarterly); because the coke layer thickens and worsens K loss and blockage, quantifying thickness guides decoking timing;
8) Write temperature control and decoking into the asphalt heat exchange maintenance procedure; because the original design omitted wall-temperature control and decoking, the root cause of coking, the procedure closes the loop against coking.

Checklist

Reference

GB/T 151-2014 Heat exchangers