E44-359 · Water Hammer and Pressure Surge · High-head pump H=120m · ★★★
Shutdown of the H=120m pump made Δp=ρcΔv stack on the static head to 1.8MPa, exceeding the pipe's 1.2 and shattering the foot valve.
[Mechanism] The high head raises the static pressure, and stacking the wave on it overloads the pipe.
[Calculation] The pressure reached 1.8, exceeding 1.2 and shattering the foot valve.
[Design Omission] No pressure-reduction protection was provided and the stacked pressure was never checked, leaving the high-head system to suffer water hammer.
1) Fit a drain valve on the high-head system to reduce the stacked static pressure, because H=120 drove the stacked pressure to 1.8 beyond 1.2 and shattered the valve; hence relief reduction;
2) Check static pressure + wave pressure ≤ allowable, because stacking exceeds the limit; hence stacked calculation;
3) Provide a slow-closing check valve to prevent reverse-flow stacking, because backflow stacks waves; hence slow closing;
4) Raise the piping rating to ≥2.0MPa, because the allowable is low; hence higher rating;
5) Close first and then stop the pump, because a direct stop stacks pressure; hence close first;
6) Install a surge arrester to cut the peak, because the wave amplitude is large; hence peak absorption;
7) Recheck by water-hammer simulation, because estimates fall short; hence simulation;
8) Write high-head protection into the design, because the lack of pressure reduction was the root cause of the hammer; hence design control.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection