E44-881 · Throttling Noise and Vibration · Throttling element · ★★★
With Δp=4.0MPa and x=0.08, choked flow produced 96dB(A)
[Mechanism] A large pressure drop makes the vena contracta reach sonic velocity and enter choked flow, sharply raising the sound power.
[Calculation] x=p2/p1=0.08<0.5, Lw≈118dB, outlet 96dB(A).
[Design Omission] No staged pressure reduction, no multi-stage trim, no silencing.
1) Reduce the pressure in stages to cut noise (4 stages each dropping 1.0MPa, stage x>0.5), since the original Δp4.0MPa and x=0.08 gave choked flow at 96dB(A), thus staging cuts the noise;
2) Verify the sound level (≤85dB(A)), since exceeding it is a nuisance and verification confirms compliance, thus checking the sound;
3) Use multi-stage trim (4-stage cage), since concentration makes noise and splitting eases it, thus staging;
4) Add a silencer (insertion loss ≥15dB), since the bare element radiates 96dB(A) and silencing lowers it, thus silencing;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the flow to steady the speed (limit v), since changing conditions make noise and control steadies it, thus controlling speed;
8) Write staged reduction and silencing into the specification, since the original lack of staging is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.
GB/T 17213.1-2015 Industrial-process control valves