E44-880 · Throttling Noise and Vibration · Throttling element · ★★★

Problem Description

The pressure drop concentrated in a single element at Δp=3.0MPa, producing 94dB(A)

Root Cause

[Mechanism] A single throttling element concentrates too much pressure drop, so the velocity rises sharply and choked-flow noise results.
[Calculation] x=p2/p1<0.5 enters choked flow, Lw≈115dB, outlet 94dB(A).
[Design Omission] No dispersion of the pressure drop, no multi-stage, no silencing.

Corrective Solution

1) Disperse the pressure drop to cut noise (multi-stage throttling instead of a single element, single stage Δp≤0.5MPa), since the original single element at Δp3.0MPa gave choked flow at 94dB(A), thus dispersing cuts the noise;
2) Verify the sound level (≤85dB(A)), since exceeding it is a nuisance and verification confirms compliance, thus checking the sound;
3) Use multi-stage trim (3~4 stages), since concentration makes noise and splitting eases it, thus staging;
4) Add a silencer (resistive, insertion loss ≥15dB), since the bare element radiates 94dB(A) and silencing lowers it, thus silencing;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the flow to steady the speed (limit v), since changing conditions make noise and control steadies it, thus controlling speed;
8) Write dispersion and staging into the specification, since the original lack of dispersion is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves