📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Throttling Temperature Drop with Noise

Throttling Temperature Drop with Noise

E44-882 · Throttling Noise and Vibration · Throttling element · ★★

Problem Description

Throttling dropped the temperature 40℃, with low-frequency noise and condensation on the pipe wall

Root Cause

[Mechanism] The Joule-Thomson effect makes the temperature drop sharply, with two-phase flow and low-frequency noise; the low temperature causes condensation on the outside of the pipe.
[Calculation] ΔT=μ_JT·Δp≈40℃; the outlet approaches the dew point and condenses.
[Design Omission] No insulation, no silencing, no pressure-drop limit.

Corrective Solution

1) Insulate to reduce the accompanying noise (insulation layer δ≥50mm on the body and downstream pipe), since the original ΔT40℃ brought low-frequency noise and condensation, thus insulation cuts the noise;
2) Verify the sound level (≤85dB(A)), since exceeding it is a nuisance and verification confirms compliance, thus checking the sound;
3) Add a silencer (resistive, insertion loss ≥10dB), since the bare pipe radiates and silencing lowers it, thus silencing;
4) Limit the pressure drop to steady it (single stage Δp≤0.5MPa reduces the temperature drop), since a large drop brings noise and limiting eases it, thus limiting the drop;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the flow to steady the speed (limit v), since changing conditions bring noise and control steadies it, thus controlling speed;
8) Write insulation and silencing into the specification, since the original lack of insulation is the root cause and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves