E44-174 · Filter Clogging and Contamination · Hydraulic Tank Breather · ★★
The clogged breather element pulled the tank under vacuum; the pump received insufficient oil and cavitated with abnormal noise.
[Clogged element] A clogged breather element pulls the tank under vacuum.
[Pump starvation] Vacuum causes insufficient suction and cavitation.
[Design Omission] No standby breather was provided and the element was never changed, causing starvation.
1) Fit two breather elements, one in service and one standby, because a single clogged element pulls tank vacuum and starves the pump, thereby keeping flow with the standby;
2) Add a differential-pressure indicator on the element to signal replacement, because clogging builds progressively, thereby signaling early change;
3) Provide pressurized make-up oil to the tank to prevent vacuum, because vacuum causes starvation, thereby pressurizing;
4) Replace the breather element on a schedule, because dust accumulation plugs it, thereby changing it regularly;
5) Provide venting at the pump inlet to prevent cavitation, because air is drawn in, thereby venting;
6) Monitor tank level and vacuum, because these are early symptoms, thereby monitoring and alarming;
7) On the trial run, verify the pump shows no starvation or cavitation, because design requirements must be measured, thereby confirming delivery;
8) Include breather reliability in the tank design, because the original lack of it is the root cause of clogging and starvation, thereby making it mandatory in design.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions