E44-175 · Filter Clogging and Contamination · Hydraulic Return Filter · ★★
The differential-pressure indicator failed without alarming; the element plugged solid, system pressure dropped, and actuators moved slowly.
[Failed indicator] A broken indicator leaves the blockage unknown.
[Solid blockage] A plugged element raises return resistance and drops pressure.
[Design Omission] No redundant indicator and no scheduled replacement were provided, causing blockage.
1) Provide redundant dual Δp indicators against failure, because a single failed indicator left the blockage unreported and pressure dropped, thereby guaranteeing alarm via redundancy;
2) Mandate element replacement on a fixed schedule, because clogging builds progressively, thereby enforcing change;
3) Add return-pressure monitoring as a backup way to detect blockage, because pressure gives a second indication if the indicator fails, thereby monitoring pressure;
4) Select an element with adequate dirt-holding capacity, because low capacity plugs easily, thereby sizing capacity;
5) Provide a bypass valve to prevent solid blockage from cutting flow, because a solid blockage stops flow, thereby bypassing;
6) Keep a traceable blockage record, because root-cause analysis needs it, thereby recording;
7) On the trial run, verify the Δp alarm and element replacement, because design requirements must be measured, thereby confirming delivery;
8) Include indicator redundancy in the filtration design, because the original single indicator is the root cause of failure, thereby making it mandatory.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions