E44-123 · Filter Clogging and Contamination · Duplex Lubricating-Oil Filter · ★★
During switching the chamber was not pre-filled with oil; one side lost pressure and flow was interrupted, cutting bearing oil supply and causing temperature rise.
[Switching] Oil flow cuts off at the instant the valve shifts.
[Calculation] During the switching interval Δt, Q=0 and the bearing oil film breaks down.
[Design Omission] No online (no-shutdown) switching procedure was provided, causing flow interruption.
1) Provide an online switching valve with a pre-fill chamber, because the new side is filled before flow is diverted, thereby avoiding flow interruption;
2) Specify a switching procedure: open the standby side and vent it first, then close the running side, because wrong sequencing cuts flow, thereby following the order;
3) Fit check valves on both legs to prevent backflow cross-talk, because mutual interference must be prevented, thereby stabilizing;
4) Monitor Δp and flow during switching, because an interruption is then detectable, thereby restoring early;
5) Provide low-point vents to prevent air binding, because air binding cuts flow, thereby venting completely;
6) Periodically verify the switching-valve seals, because internal leakage mixes the chambers, thereby maintaining isolation;
7) On the trial run, rehearse switching and confirm no flow interruption, because design requirements must be measured, thereby confirming delivery;
8) Put the switching procedure into the filter operation card, because wrong sequencing is the root cause, thereby institutionalizing prevention.
GB/T 3766-2015 Hydraulic fluid power - General technical conditions