E44-058 · Valve Selection and Internal Leakage · Gate Valve · ★★
A gate valve half-open creates a high-velocity jet behind the disc that cavitates; the seat erodes and leaks, still passing 1.8L/min after shutoff
[Mechanism] Half-open throttling raises local velocity and drops pressure below pv, causing cavitation; the jet erodes the seal.
[Calculation] A 30% opening triples local v, pressure drops and cavitation forms, eroding the sealing face 0.3mm deep.
[Design Omission] No full-open/full-closed position requirement and no separate throttling valve - scouring caused internal leakage.
1) Limit the gate valve to full-open or full-closed and forbid throttling, since half-opening tripled the post-disc jet velocity, dropped pressure below pv and caused cavitation erosion, removing the cavitation source and protecting the sealing face;
2) Provide a separate throttling valve (e.g. a V-port ball valve) for control, since a throttling valve is built for high-velocity differential pressure while the gate valve is for isolation, dividing duties so neither is damaged;
3) Choose an anti-cavitation valve type or hardened seat, so even if mistakenly throttled the hard face resists cavitation scouring, lowering leakage risk;
4) Hardface the seat with a wear layer, since 0.3mm erosion loses the seal and hardfacing extends life, lengthening the overhaul interval;
5) Fit online leak detection, since it still passes 1.8L/min after shutoff and needs monitoring, catching seal failure in time;
6) Limit gate-valve position on the operating permit to two settings (open/closed), since manual half-opening caused it, eliminating misoperation by rule;
7) Test shutoff leakage ≤0.1L/min at commissioning, since shutoff sealing is the gate valve's job and needs measurement, accepting on proof;
8) Put opening management into the operating procedure, since a management gap caused half-open throttling, fixing correct use by procedure.
GB/T 12234-2017 Steel gate valves for oil and gas industry