E44-398 · Water Hammer and Pressure Surge · Check Valve Shattered by Hammer · ★★
Water hammer Δp=1.3MPa exceeds the valve-body rating, shattering the check-valve disc; fragments jammed the pump and the line had to be shut down for teardown and inspection.
[Over-Valve Rating] The hammer drove Δp to 1.3 over the body rating, shattering the disc.
[Jamming] Fragments jammed the pump and stopped the line.
[Design Omission] No hammer attenuation and no valve rating upgrade — the hammer shattered the valve.
1) Provide surge absorption / slow closure to hold Δp within the valve rating; the 1.3 hammer shattered the disc and jammed the pump, so attenuate the hammer to protect the valve;
2) Upgrade the check-valve pressure rating; the low rating let it shatter, so raise the class;
3) Check the hammer peak against the valve rating; shattering came from an uncalculated peak, so compute it;
4) Fit a temporary strainer at the pump suction to catch fragments; debris damages the pump, so add interim filtration;
5) Use a slow-closing check valve to cut the source amplitude; the source surge was large, so close slowly;
6) Provide an overpressure interlock; overpressure is a hazard, so interlock for protection;
7) Recheck by water-hammer simulation, because estimates fall short; hence simulation;
8) Write valve protection into the design; the missing attenuation was the root cause, so close the loop at design.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection