Running below the minimum flow causes recirculation and cavitation

E44-215 · Pump Selection & Cavitation · Multistage Centrifugal Pump D85-45x6 · ★★★

Problem Symptom

The pump ran continuously at 0.25Q although the minimum flow should be 0.4Q or more, recirculation at the impeller inlet cavitated and the inlet edge pitted

Root Cause

[Cavitation] Flow below the minimum continuous flow produces a recirculation vortex at the impeller inlet, and the local low pressure causes recirculation cavitation.
[Calculation] Below Qmin the inlet recirculation creates a low-pressure vortex zone where the local pressure falls below Pv, the bubbles collapse and pitting occurs.
[Design Omission] No minimum flow recirculation protection was fitted and low-flow continuous running was permitted, so cavitation occurred.

Correct Solution

1) Fit a minimum flow recirculation valve to guarantee Q of 0.4Q or more: the recirculation valve makes up the flow, so the machine stays out of the recirculation zone;
2) Determine the minimum continuous flow from the manufacturer Qmin: Qmin is the cavitation boundary, so the limit is not exceeded;
3) Provide a bypass on the discharge returning to the suction vessel: the bypass dumps flow, so the minimum flow is maintained;
4) Raise a low-flow alarm and interlock: low flow is insidious, so this provides warning;
5) Select an impeller with an inlet structure that resists recirculation: the structure improves the recirculation, so the effect is mitigated;
6) Use variable speed to match the actual demand and avoid throttling down to low flow: throttling reduces Q, so the duty is optimised;
7) Commission the pump at low flow and verify the recirculation protection operates: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the minimum flow protection in the design: the original absence of protection was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »