Eccentric reducer fitted backwards at the pump suction traps gas and causes cavitation

E44-216 · Pump Selection & Cavitation · Horizontal Centrifugal Pump IS80-65-160 · ★★

Problem Symptom

The eccentric reducer at the suction was installed flat side down instead of flat side up, forming a gas pocket, so after start-up the gas lock reduced the flow and cavitation noise appeared

Root Cause

[Cavitation] Installing the eccentric reducer backwards makes a gas pocket form at the pipe crown and the gas slug enters the impeller and cavitates.
[Calculation] With the flat side down the step at the top traps gas, the pocket volume grows with time, the effective flow area falls and the slug collapses in the pump.
[Design Omission] The installation did not follow the flat-side-up principle for eccentric reducers and no fool-proofing was provided, so it was fitted the wrong way round.

Correct Solution

1) Install the eccentric reducer flat side up: with the flat side up no gas is trapped, so the gas travels with the liquid and no pocket forms;
2) Mark the flat side orientation clearly on the drawing and add fool-proofing marks: crews readily fit it the wrong way round, so the marking prevents the error and the assembly is correct first time;
3) Fit an air vent valve at the high point of the suction pipe: residual gas collects at the top, so it is released there;
4) Avoid local high points in the suction pipe: an upward step traps gas, so no pocket can form;
5) Prime the pump and purge it thoroughly before start-up: residual gas causes cavitation, so it must be purged clean;
6) Watch the inlet pressure during start-up to confirm it is stable: a gas lock causes pressure fluctuation, so this confirms there is no gas;
7) Commission the pump and verify the flow and inlet pressure meet the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the eccentric reducer orientation in the installation standard: fitting it backwards was the root cause, so the standard must always include it.