E44-217 · Pump Selection & Cavitation · Oversized Centrifugal Pump IS150-125-315 · ★★★
The flow margin at selection was 50%, but the pump ran continuously at 0.5Q, so inlet recirculation cavitated and the efficiency fell to 55%
[Cavitation] The excessive margin means the pump runs continuously at low flow, where inlet recirculation cavitates and the efficiency is low.
[Calculation] The operating point shifted to 0.5Q against a minimum flow Qmin of 0.6Q, so the inlet recirculation formed a low-pressure vortex and the local pressure fell below Pv, causing cavitation.
[Design Omission] The selection margin was excessive and the pump was not chosen against the actual flow, so it ran off design continuously.
1) Reselect against the actual flow and limit the margin to 10% maximum: an excessive margin leaves the pump at low flow, so this brings the operating point back into the high-efficiency region;
2) Where an oversized pump is already installed, trim the impeller diameter to match the actual duty: trimming shifts the Q-H curve, so the operating point moves back into place;
3) Use variable speed to match the actual demand: reducing the speed reduces the capability, so the duty is optimised;
4) Fit a minimum flow recirculation valve: at low flow cavitation occurs, so the valve makes up the flow;
5) Replace the single large pump with several smaller pumps: staged regulation is flexible, so each pump stays in its efficient region;
6) Check that the operating point falls in the high-efficiency region: there NPSHr is low, so both benefits are obtained;
7) Commission the pump and measure the operating point flow, efficiency and inlet pressure: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include selection against the actual flow in the procedure: the original excessive margin was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH