E44-218 · Pump Selection & Cavitation · Light Hydrocarbon Transfer Pump AY65-40 · ★★★
The medium was propane (Pv 0.85MPa), leaving only NPSHa of 1.2m against NPSHr of 2.0m, so the impeller cavitated and the flow was unsteady
[Cavitation] A volatile medium has an extremely high vapour pressure, so the Pv/rho*g term in NPSHa is huge and cavitation is very likely.
[Calculation] NPSHa=Pa/rho*g-Hs-hf-Pv/rho*g; for propane with Pv of 0.85MPa the last term reaches a pressure difference of the order of 170m, so NPSHa is depressed severely.
[Design Omission] No pump with a low NPSHr was specially selected for the high-Pv medium and the suction side pressure was insufficient, so cavitation occurred.
1) Select an ultra-low NPSHr pump (with inducer) against the actual Pv of the medium: the inducer markedly lowers NPSHr, so the pump suits the high-Pv service;
2) Raise the operating pressure of the suction vessel to lift NPSHa: a higher vessel pressure raises the Pa/rho*g term, so this makes up the difference;
3) Increase the suction submergence and raise the suction vessel to lift NPSHa: the elevation difference raises NPSHa, so this compensates;
4) Keep the suction pipe insulated to stop the medium warming and Pv rising further: warming raises Pv, so the temperature is controlled;
5) Enlarge the suction pipe diameter to lower velocity and cut hf: hf consumes NPSHa, so the loss is reduced;
6) Install inlet pressure monitoring with a cavitation interlock: the vacuum is the precursor, so this protects the machine;
7) Commission the pump under the actual medium conditions and verify there is no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include a dedicated selection procedure for high-Pv media in the design: the original lack of a dedicated selection was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH