Insufficient submergence of the suction pool draws in a vortex with gas

E44-214 · Pump Selection & Cavitation · Vertical Axial Pump 350ZLB · ★★★

Problem Symptom

The bellmouth was submerged only 0.6m against a design minimum of 1.2m, a suction vortex formed on the water surface and entrained gas, the flow dropped 12% and the vibration was large

Root Cause

[Cavitation] Insufficient submergence lets a suction vortex form on the surface, and the vortex core draws air down to the impeller where it cavitates.
[Calculation] The critical submergence S is at least d(0.5+2.0Fr) with Fr=v/sqrt(g*d); the actual 0.6m is below the required 1.2m, so the vortex entrains gas.
[Design Omission] The suction pool submergence and the bellmouth were not designed to the anti-vortex criteria, so gas was entrained.

Correct Solution

1) Increase the bellmouth submergence to 1.2m or more: with adequate submergence no vortex forms, so no gas is entrained;
2) Fit anti-vortex plates or baffles in the suction pool: these break up the vortex structure and so the vortex is eliminated;
3) Fit a cruciform anti-vortex plate on the bellmouth: this suppresses the rotation, so no vortex core exists;
4) Control the bellmouth approach velocity at 1.0m/s maximum: a high velocity readily forms a vortex, so Fr is reduced;
5) Lay out the suction pool to the pump station design code: the geometry influences the flow pattern, so the approach flow is made uniform;
6) Check the submergence against the minimum water level: the low-water condition is the most severe, so it is covered;
7) Commission the pump at the lowest water level and confirm no vortex and no gas entrainment: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the anti-vortex submergence in the pump station design: the original insufficient submergence was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »