E44-213 · Pump Selection & Cavitation · Gas-Bearing Medium Transfer Pump IH100-80-160 · ★★★
The medium carried 8% gas against a design limit of 2%, gas-liquid separation at the impeller inlet produced a gas lock, the flow dropped 18% and the head fluctuated
[Cavitation] The excessive gas content causes gas-liquid separation at the impeller inlet and the gas slugs occupy the flow passages, forming cavitation.
[Calculation] At 8% gas the effective flow area falls by about 8% and the slugs expand in the low-pressure zone and block the flow, so the flow drops 18%.
[Design Omission] The pump was not selected for gas-bearing duty and the feed was not degassed, so cavitation occurred.
1) Install a degassing vessel ahead of the feed to bring the gas content to 2% maximum: degassing reduces the gas slugs, so the flow passages stay clear;
2) Select a special gas-tolerant cavitation-resistant impeller (with inducer or tangential venting): it can vent the gas, so it resists gas cavitation;
3) Fit an air vent at the high point of the suction pipe: gas collects at the top, so it is released there;
4) Reduce the velocity on the suction side to limit vortexing: high velocity entrains gas, so less gas is carried;
5) Raise the liquid level in the suction vessel to prevent a vortex entraining gas: the vortex draws in air, so gas entrainment is avoided;
6) Rate the pump down when the medium carries gas: gas reduces the capability, so a margin is retained;
7) Commission the pump and measure the gas content and flow against the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the gas content constraint in the selection: the original excess gas was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH