E44-212 · Pump Selection & Cavitation · Low Specific-Speed Centrifugal Pump IS50-32-250 · ★★
The specific speed was ns=45 (the duty calls for ns of at least 80), the efficiency was only 58% against 75% or more expected of that class, NPSHr was high off design and slight cavitation occurred
[Cavitation] A specific speed that does not match the duty keeps the pump away from its high-efficiency region, and NPSHr is high off design.
[Calculation] ns=3.65*n*sqrt(Q)/H^0.75=45; such a low-speed-ratio type is unsuitable for large flows, has low efficiency and a steep NPSHr curve.
[Design Omission] The pump type was not matched using ns=3.65*n*sqrt(Q)/H^0.75, so the selection was wrong.
1) Recalculate with the ns formula and select a pump type with a matching specific speed: ns determines the pump structure and efficiency, so this brings the efficiency back to 75% or more;
2) For large-flow, low-head duty select a high-ns mixed-flow pump: a high ns suits a large Q, so the type is matched;
3) Place the selection in the middle of the high-efficiency region: in the middle the efficiency is high and NPSHr is low, so both benefits are obtained;
4) Avoid selecting inefficient multistage pumps for small-flow, high-head duty: off-design duty cavitates, so the selection is made sensibly;
5) Check the NPSHr curve for the specific speed selected: the cavitation characteristics differ between specific speeds, so this covers the duty;
6) Where necessary change to multistage or double-suction to adjust the ns: the structure changes the ns, so the duty is matched;
7) Commission the pump and verify the efficiency and inlet pressure meet the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the specific speed matching in the selection report: the original absence of the match was the root cause, so the design must always include it.