Oversized head selection pushes the duty off design and causes cavitation

E44-211 · Pump Selection & Cavitation · Oversized Centrifugal Pump IS200-150-315 · ★★★

Problem Symptom

The required head was 32m but 50m was selected, so the actual operating point shifted into the 1.4Q high-flow region, NPSHr rose to 4.2m against NPSHa of 3.5m and cavitation occurred

Root Cause

[Cavitation] The oversized head selection shifts the operating point to the right into high flow, where NPSHr rises steeply.
[Calculation] The intersection of the piping characteristic and the pump curve moves to the right; raising Q from 1.0 to 1.4 raises NPSHr in proportion to Q squared by about a factor of 2, from 3.0 to 4.2m against NPSHa.
[Design Omission] Head was selected with a blind margin and the pump was not chosen against the actual piping resistance, so cavitation occurred.

Correct Solution

1) Select the head from a careful calculation against the actual piping characteristic: an excessive margin shifts the operating point, so this brings it back into the high-efficiency region;
2) Keep the head margin between 5 and 10%: an excessive margin pushes the duty off design, so a moderate margin is applied;
3) Where an oversized pump is already installed, trim the impeller diameter to reduce the head: as D falls H falls with D squared, so the operating point moves back;
4) Install a control valve on the discharge to correct the operating point: throttling raises the piping resistance and shifts the point left, giving a temporary correction;
5) Use variable speed to match the actual demand: reducing the speed reduces the head and the throttled duty is optimised;
6) Moving the operating point back lowers NPSHr: NPSHr varies with Q squared, so the cavitation is eliminated;
7) Commission the pump and measure the operating point flow, head and inlet pressure: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the selection against the actual piping resistance in the procedure: the original blind margin was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH