Blocked suction strainer lowers NPSHa and causes cavitation

E44-210 · Pump Selection & Cavitation · Process Feed Pump IH80-65-160 · ★★

Problem Symptom

Progressive blockage of the suction strainer raised the pressure drop from 0.3 to 1.2m, dropping NPSHa from 3.0 to 2.1m against NPSHr of 2.6m, and cavitation noise appeared

Root Cause

[Cavitation] The progressively blocked strainer increases the local resistance and the suction-side loss consumes NPSHa.
[Calculation] NPSHa equals Pa/rho*g-hf and so on; with the strainer differential head rising from 0.3 to 1.2m NPSHa falls by 0.9m, from 3.0 to 2.1m against NPSHr.
[Design Omission] No differential pressure monitoring was fitted to the strainer, so the blockage raised no alarm and cavitation followed.

Correct Solution

1) Fit a differential pressure gauge to the suction strainer and set a cleaning threshold: as the blockage raises the differential head and consumes NPSHa, cleaning in good time is required;
2) Select a strainer with sufficient flow area (at least 3 times the pipe cross-section): a large area means low velocity and a small pressure drop, so the differential head stays small;
3) Alarm and interlock when the differential pressure exceeds its limit: manual inspection is easily missed, so this gives automatic warning;
4) Provide dual strainers that can be switched for cleaning without stopping the pump: cleaning requires a shutdown, so continuous operation is maintained;
5) Include the worst-case dirty strainer pressure drop in the NPSHa check: the dirtiest condition is the most severe, so the worst case is covered;
6) Install inlet pressure monitoring as a cavitation warning: the vacuum is the precursor, so this protects the machine;
7) Commission the pump and test a half-blocked condition to confirm NPSHa is sufficient: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the strainer differential pressure monitoring in the design: the original absence of monitoring was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH