Self-priming pump suction lift exceeds the allowable suction head and fails to draw liquid

E44-003 · Pump Selection & Cavitation · Self-Priming Pump ZW50-20 · ★★

Problem Symptom

The suction lift of 4.5m exceeded the allowable suction head of 3.8m; the pump delivered no liquid on start-up, needed priming 3 times and failed 15 times a month

Root Cause

[Suction Head Limit] The allowable suction head is Hs=(Pa-Pv)/rho*g-hf-v2/2g; a lift of 4.5m against an allowable 3.8m leaves insufficient negative pressure at the inlet to draw the liquid.
[Air Lock] Air ingress in the suction pipe forms an air lock and defeats the self-priming action, dropping the volumetric efficiency to 40%.
[Design Omission] The suction lift was not controlled to 3m maximum and the suction pipe was never subjected to a tightness test, so the excessive suction head prevented the pump from drawing liquid.

Correct Solution

1) Lower the suction lift to 3m maximum (was 4.5m): with the allowable suction head Hs=(Pa-Pv)/rho*g-hf-v2/2g, every 0.1m of excess raises the inlet vacuum, so the inlet pressure stays above the vapour pressure and liquid is drawn normally;
2) Carry out a tightness test on the suction pipe (holding 0.05MPa.min under vacuum with no drop) to eliminate air leaks: a leak forms an air lock within the suction head and drops the volumetric efficiency to 40%, so the self-priming action is restored;
3) Fit a foot valve and a screen at the suction inlet: the foot valve holds liquid back and the screen excludes debris, so the pump starts with liquid and neither runs dry nor forms an air lock;
4) Increase the suction pipe bore to DN65 (was DN50) to bring the velocity down to 1.2m/s: suction losses vary as v2, so reducing velocity cuts hf from 0.8m to 0.3m and increases the Hs margin;
5) Fill the pump casing and the suction pipe with liquid and purge all air before the first start: a self-priming pump relies on the liquid retained in the casing to establish the vacuum, so one start delivers liquid without repeated priming;
6) If the suction lift is still large, switch to flooded suction or pressurised feed (inlet pressure at least 0.02MPa): flooding converts the suction head into a positive-pressure push, so the suction head limit no longer applies at all;
7) Trial-draw to confirm a self-priming time of 3min maximum with continuous delivery: the self-priming time is an overall indication of sealing and clearances, so the measurement confirms the reliability;
8) Write the allowable suction head and maximum suction lift into the installation manual: crews often lengthen the suction pipe on site and exceed the suction head, so the manual guides installation within limits.