Excessive suction lift on a vertical centrifugal pump causes cavitation at the impeller inlet

E44-051 · Pump Selection & Cavitation · Vertical Centrifugal Pump · ★★

Problem Symptom

The high suction lift made NPSHa=2.0m less than NPSHr=3.2m, cavitation pits 1.5mm deep appeared at the impeller inlet, and the head fell from 32m to 28.2m

Root Cause

[Cavitation Mechanism] Insufficient inlet pressure brings the local pressure at the impeller inlet below the saturation vapour pressure of the liquid; the flow flashes into vapour and the bubbles collapse in the high-pressure zone, hammering the metal into pits.
[Calculation] The measured NPSHa=2.0m against NPSHr=3.2m leaves a shortfall against the requirement NPSHa at least NPSHr+0.5=3.7m of 1.7m; the suction pipe friction h_f=lambda*L/d*v2/2g=0.025x30/0.15x0.204 is about 1.0m, which is on the high side.
[Design Omission] The pump was not selected against NPSHa at least NPSHr+0.5, the suction lift was taken too large and the suction pipe resistance was never checked, so cavitation produced pits and a head loss.

Correct Solution

1) Lower the pump installation height or switch to flooded suction so that NPSHa is at least 3.7m: the measured NPSHa=2.0 falls short of the required 3.7 by 1.7m, which caused the cavitation, so raising the installation or flooding restores the margin;
2) Enlarge the suction pipe diameter to reduce velocity and cut h_f: the original h_f of about 1.0m was large and consumed the margin, so a larger pipe lowers h_f;
3) Fit a strainer at the suction but limit its resistance to 0.3m maximum: filter resistance adds to the losses and eats into NPSHa, so the resistance must be capped;
4) Select a cavitation-resistant impeller (double-suction or with inducer): a cavitation-resistant profile raises the NPSHr margin, so the resistant type is chosen;
5) Calculate the required NPSHr: NPSHr defines the demand, so it must be computed;
6) Install a vacuum gauge at the suction for monitoring: the vacuum gauge shows the inlet pressure and provides early warning;
7) Commission the pump and measure the head and the inlet pressure against the design values: meeting them proves that no cavitation occurs;
8) Include the cavitation margin in the pump selection calculation: the original omission of this check was the root cause of the cavitation, so selection must always include it.

Checklist