Circulating water pump operating away from its rated point overloads the motor and trips it

E44-002 · Pump Selection & Cavitation · Circulating Water Pump IS80-65-160 · ★★

Problem Symptom

The actual flow of 95m3/h far exceeded the rated 60m3/h, motor current exceeded rating by 28%, bearing temperature rose quickly and the unit tripped 6 times a month

Root Cause

[Operating Point Deviation] The piping resistance was calculated too low, shifting the system resistance curve to the right and moving the operating point to the high-flow region Q=95 against a rated 60, so the shaft power P proportional to QH rose.
[Overload] The actual power P=kQH/eta=1.2x95x32/0.6=6.1kW exceeds the 5.5kW motor rating by 11%.
[Design Omission] No check was made of the intersection between the piping characteristic and the pump performance curve and no control valve was fitted, so the operating point became unstable in the high-flow region.

Correct Solution

1) Recalculate the piping resistance curve H=H0+KQ2 and intersect it with the pump performance curve to fix the operating point: the original resistance coefficient K was too small and moved the intersection out to 95m3/h, so this locks in the true duty flow and avoids oversizing the pump;
2) Install a control valve on the discharge pipe and limit its opening to bring the operating point back into the rated 60m3/h region: throttling the valve raises the system resistance and pulls the intersection back into the high-efficiency zone, so the shaft power falls and the motor no longer overloads;
3) Trim the impeller according to the affinity law (Q proportional to D, H proportional to D squared) or replace it with a suitable model so the rated point matches the actual 60m3/h: trimming shifts the whole pump curve down, so the pump still operates at rated duty in the actual piping system;
4) Select the motor from the actual shaft power P=KQH/eta multiplied by 1.1 and check the rated current: the original 5.5kW motor running continuously at 6.1kW with 28% overcurrent will trip on thermal protection, so a 10% margin keeps the machine safe;
5) Set dual-parameter alarming on flow and current (warning at current at or above 90% of rating): looking at flow alone misses the way the shaft power varies with H, so this gives early warning of the overload and prevents the trip;
6) Enlarge the discharge pipe from DN80 to DN100 to lower velocity and reduce the system resistance coefficient K: because the resistance varies as 1/d to the power of 5, the operating point shifts left towards rated, saving energy and cutting the overload risk;
7) During commissioning measure flow, head and current and compare them against the curves: design values often deviate from reality, so the data validates the match rather than relying on calculation alone;
8) Make the duty point check (the curve intersection) a mandatory entry in the selection report: a missed check is the root cause of the operating point deviation, so control at the source is achieved.

Checklist

References

GB/T 5657-2013 Centrifugal Pumps - Technical Conditions