E44-001 · Pump Selection & Cavitation · Feedwater Pump DFBG50-200 · ★★★
At the pump suction the available NPSH was NPSHa=2.1m, below the required NPSHr=3.5m; cavitation dropped the head by 18%, 12 pitting pits formed on the impeller, and after 3 months of running the blades perforated, causing 4 shutdowns
[NPSH Margin] The available NPSH is NPSHa=Pa/rho*g+Hs-hf-Pv/rho*g; with an installation height Hs=3.2m the inlet pressure is reduced and only 2.1m of margin remains.
[Vapour Collapse] The local pressure at the impeller inlet falls below the saturation vapour pressure Pv, and bubble collapse produces micro-jets that hammer the metal; the pitting rate is proportional to (NPSHr-NPSHa) to the power of 3.
[Design Omission] The available NPSH was never checked, the installation height was not lowered and the suction pipe was not enlarged, so NPSHr=3.5>NPSHa=2.1 and the impeller perforated through pitting.
1) Lower the pump installation height to 2.7m maximum (was 3.2m): every 1m of height reduction raises the inlet static pressure by about 0.01MPa and lifts NPSHa from 2.1m to at least 4.0m, so the inlet pressure stays above the vapour pressure of the medium, bubbles no longer collapse and the impeller pitting perforation is eliminated;
2) Enlarge the suction pipe from DN150 to DN200 and reduce the number of elbows: dropping the velocity from 2.6m/s to 1.5m/s cuts the friction and local loss hf from 1.4m to 0.6m, so NPSHa rises and the cavitation margin increases;
3) Use an eccentric reducer on the suction pipe installed flat side up: this keeps the pipe crown level with the pump nozzle so accumulated liquid and gas are carried downstream into the pump chamber, preventing gas pockets that would cause cavitation and vibration;
4) Fit an inducer at the impeller inlet: the pre-rotation produced by the inducer raises the inlet pressure by about 0.3~0.5m and delays bubble formation, improving the required NPSHr of the pump by about 1m;
5) Install a Y-type strainer at the suction and clean it every shift: debris blockage causes a sudden rise in the suction local loss and a further drop in NPSHa, so keeping the inlet flow path clear prevents cavitation from recurring after a blockage;
6) Check the required NPSH curve from the manufacturer data and keep at least 0.5m of margin at the high-flow point: NPSHr rises steeply at high flow, so this keeps NPSHa>NPSHr over the whole operating range and out of the cavitation zone;
7) Perform a cavitation test on the first unit, with a head drop of no more than 3% as the acceptance criterion: a sudden head drop is the direct signature of cavitation, so the test confirms by measurement whether the margin is genuinely sufficient;
8) Make the NPSH check a mandatory item in design review: most cavitation originates from a missed check at the selection stage, so this prevents recurrence of the same problem at process level.
GB/T 13006-2013 Centrifugal Pumps - Efficiency