Support Loosening from Piping Vibration

E44-818 · Piping Supports and Thermal Expansion · Piping System · ★★

Problem Description

Piping vibration, support loosening, falling off

Root Cause

[Mechanism] Piping vibration loosens and releases the supports.
[Calculation] Vibration loosens the support bolts, allowing displacement >5mm and fall-off.
[Design Omission] Neither securing nor vibration reduction was provided — so securing must be added.

Corrective Solution

1) Secure the supports against loosening (tighten with a torque wrench, add locking): because the original vibration loosened the bolts, allowed displacement >5mm and brought fall-off, securing the supports prevents it;
2) Add vibration-damping pads (fit rubber damping pads under the supports): because vibration loosens and damping relieves it, vibration is reduced;
3) Weld the anchorage firmly (weld the anchor plate firmly to prevent release): because looseness releases it and welding secures it, the weld is made;
4) Check the support spacing (set the span by the vibration frequency): because sparse supports vibrate and the check densifies them, the spacing is checked;
5) Monitor the loosening condition (check the torque / displacement periodically, with alarms): because progressive loosening brings fall-off closer and early awareness helps, loosening is monitored;
6) Perform a vibration test (start up and record the amplitude): because the original lack of testing left the loosening undiscovered, the test identifies the vibration points, so the test is run;
7) Control the excitation source (keep the speed away from critical): because the source causes vibration and control relieves it, the source is controlled;
8) Write the support securing and vibration reduction into the maintenance card: the original lack of securing was the root cause of the vibration, so maintenance controls the work and the supports stay firm.

Checklist

Reference

GB/T 17116.1-2018 Pipe supports and hangers