E44-494 · Filter Blockage and Fouling · Gas Manifold Filter · ★★
High-pressure gas throttles and cools; entrained water freezes and blocks; gas cutoff downstream
[Mechanism] Throttling at the orifice cools the gas and freezes the water.
[Calculation] Throttling ΔT makes local temperature <0℃, water freezes and seals the orifice, flow cuts out.
[Design Omission] No drying and no heat tracing; ice blockage results.
1) Add drying to the gas source to achieve a dew point <-40℃, because the original entrained water, throttling <0℃ freezing and flow cutout caused the blockage, so drying prevents ice;
2) Heat-trace and insulate the filter housing, because cold freezes it, so heat tracing is used;
3) Preheat before throttling, because throttling lowers temperature, so preheating is used;
4) Set a low-pressure alarm, because blockage drops pressure, so an alarm is provided;
5) Remove water upstream of the filter, because water freezes, so water removal is used;
6) Circulate at low flow to prevent stagnation, because stagnation freezes, so circulation is used;
7) Inspect the desiccant regularly, because saturation lets moisture through, so the desiccant is inspected;
8) Write drying and heat tracing into the gas-manifold specification, because the lack of drying was the root cause of ice, so the gas-manifold spec governs.
GB/T 14295-2019 Air filters