E44-299 · Valve Selection and Internal Leakage · Plastic-lined ball valve Q41F-10 DN80 · ★★
At an 80℃ medium the plastic liner thermally expanded and deformed, jamming the trim and failing to stroke.
[Deformation] The plastic liner has a high expansion coefficient; over-temperature makes the layer bulge and jam the trim.
[Jam] The bulge occupies the clearance and the trim will not move.
[Design Omission] The medium temperature was not held within the plastic rating and no heat-resistant plastic was chosen — the plastic-lined valve jammed.
1) Keep the medium temperature within the plastic rating (e.g., ≤60℃); 80℃ bulged the liner and jammed the trim, failing stroking, so control the temperature;
2) On over-temperature sections switch to a PFA-type heat-resistant liner; the original plastic could not take 80℃, so make it temperature-resistant;
3) Add heat sinks on the body or cool the medium; heat is the deformation source, so lower the temperature;
4) Leave assembly clearance to absorb thermal expansion; expansion jams, so leave clearance;
5) Periodically inspect the liner for bulging; bulging is gradual, so diagnose early;
6) Switch to a metal hard seat to remove the plastic risk; metal does not expand and jam, so make it durable;
7) Set a torque alarm to detect jamming; jamming raises torque, so monitor it;
8) Bring temperature and plastic grade into selection; the mismatch was the cause of jamming, so gate it at design.
GB/T 37811-2019 Fluoroplastic-lined valves - General technical specifications