Damaged O-Ring in the Quick Coupling

E44-603 · Seal Leakage · Quick Coupling · ★★

Problem Symptom

Joint leaks, O-ring damaged

Root Cause

[Mechanism] The damaged O-ring leaks.
[Calculation] The damage causes the leak.
[Design Omission] The ring was not replaced, not protected and not inspected - the damage was left in place.

Correct Solution

1) Change the quick coupling O-ring (NBR or FKM selected for the medium); the original damaged ring leaked, so replacing it stops the leak;
2) Protect the ring against extrusion (fit a back-up ring); extrusion damages it, and the back-up ring prevents that;
3) Select an oil-resistant ring (FKM); oil attack damages it, and an oil-resistant material prevents that;
4) Apply ring grease to prevent ageing (compatible grease); ageing damages the ring, and the grease prevents it;
5) Inspect the ring condition (at every overhaul); damage develops gradually and then leaks, so the ring is inspected;
6) Limit the insertion and withdrawal force (do not force it, this cuts the ring); forcing it damages the ring, and limiting the force prevents that;
7) Clean the coupling and remove sand (blow through); sand damages the ring, and cleaning prevents that;
8) Write the ring replacement and the protection into the maintenance card; the original failure to replace the ring was the root cause of the damage, so the maintenance card closes the loop.

Checklist

References

GB/T 3452.1-2005 O-Rings for Hydraulic and Pneumatic Applications