E44-621 · Level Control Failure · Double Flange · ★★★
Diaphragm damage, signal loss
[Mechanism] A damaged diaphragm loses the pressure transfer.
[Calculation] The damage causes the indication to be lost.
[Design Omission] No corrosion-resistant material was selected, and the diaphragm was neither inspected nor replaced, so it failed.
1) Replace with a corrosion-resistant diaphragm (Hastelloy C276 or tantalum, resistant to chloride >20000ppm), because the original 316L diaphragm pitted through in chloride media (Cl->500ppm), losing the pressure transfer and the indication, while the corrosion-resistant material resists pitting, thereby restoring measurement;
2) Choose a thicker diaphragm for strength (thickness from 0.2mm to 0.4mm, pressure rating +50%), because a thin diaphragm fails under particle erosion and a thick one withstands it, thereby extending service life;
3) Control media corrosivity (add inhibitor to keep the corrosion rate <0.1mm/a), because corrosion damages the diaphragm and controlling it reduces the attack, thereby protecting the diaphragm;
4) Calibrate the zero indication (calibrate on commissioning, error ≤0.1%FS), because a damaged diaphragm causes loss and calibration verifies it, thereby confirming the reading;
5) Add a seal and purge to prevent abrasion (fill-fluid density 1.2, isolate the solids), because slurry erodes the diaphragm and isolation protects it, thereby preventing abrasion;
6) Check the diaphragm condition (strip and measure its thickness at each inspection, replace once thinned by >10%), because gradual damage leads to failure and inspection catches it early, thereby allowing preemptive replacement;
7) Limit the pressure to the diaphragm range (operating pressure ≤90% of span), because overpressure over-stretches and damages the diaphragm and limiting it protects, thereby stabilizing operation;
8) Write the corrosion-resistant diaphragm replacement into the maintenance card (interval ≤2 years), because the omitted corrosion-resistant selection was the root cause of the failure and freezing it into the maintenance card enforces maintenance.
GB/T 17614.1-2008 Transmitters for use in industrial-process control systems