E44-620 · Level Control Failure · Glass-Plate Level Gauge · ★★
Glass cracking and leakage
[Mechanism] The glass cracks under impact.
[Calculation] The cracking causes leakage.
[Design Omission] No tempered glass was selected, no guard was provided, and it was not inspected, so the glass cracked.
1) Replace with a tempered glass plate (tempered borosilicate glass, pressure rating ≥1.6MPa, thermal shock resistance ΔT≤120℃), because the original ordinary glass cracked from tool impact or from severe temperature swings on startup and shutdown (ΔT>80℃) and cracked open at once, while tempered borosilicate resists impact and thermal shock, thereby withstanding pressure and temperature without cracking;
2) Add a guard against impact (acrylic guard, ≥20mm clear of the plate face), because knocks during rounds or maintenance crack the glass and the guard absorbs the impact, thereby preventing mechanical breakage;
3) Control the temperature change rate (≤10℃/min), because a sudden change overstresses the glass from the inside-outside temperature difference and slowing it lowers the stress, thereby preventing thermal cracking;
4) Choose a mica liner against corrosion (mica sheet lining, 0.2mm thick), because media corrosion weakens the glass surface until it cracks and the mica isolates the corrosion, thereby extending service life;
5) Tighten evenly to prevent uneven cracking (tighten diagonally, bolt torque ±10%), because uneven clamping over-compresses the glass locally and even tightening balances it, thereby preventing uneven cracking;
6) Check for cracking (look for craze cracks weekly), because gradual cracking leads to leakage and inspection catches it early, thereby allowing preemptive replacement;
7) Limit temperature and pressure to design values (operating temperature ≤90% of design, pressure ≤ rated), because exceeding them cracks the glass and controlling the parameters protects it, thereby stabilizing operation;
8) Write the tempered glass and guard into the assembly card, because the omitted tempered glass and guard were the root cause of the cracking and freezing them into the assembly card enforces assembly control.
HG/T 21550-1993 Level gauges