E44-016 · Two-Phase Flow and Gas Binding · Tank Suction Pipe · ★★

Problem Description

The suction inlet was only 0.2m below the oil surface; a vortex sucked in air, making the pump noisy and the flow fluctuate by ±20%.

Root Cause

[Vortex] The low liquid level forms a funnel vortex at the inlet; the air entrainment q∝√(H), so volumetric efficiency drops.
[Gas Binding] Compressed air makes the pump discharge pressure pulsate, and the flow becomes unstable.
[Design Omission] No minimum liquid level was set, and no anti-vortex plate was added at the inlet; air entry caused the fluctuation.

Corrective Solution

1) Submerge the inlet to ≥2D below the minimum level to prevent vortexing; at only 0.2m depth the funnel vortex sucked in air and cut volumetric efficiency, so enough submergence breaks the vortex core;
2) Add an anti-vortex plate or flow hood at the inlet; the plate blocks the swirl and eliminates the funnel vortex, so no air is drawn in;
3) Interlock the pump to trip at minimum level; an excessively low level always generates a vortex and air draw, so tripping at the limit protects the pump;
4) Provide both a sight gauge and a remote transmitter for the tank level; a single gauge is easily misread into a low level, so double confirmation is used;
5) Form the suction inlet as a bell mouth to stabilize flow; the bell mouth expands and decelerates the stream, giving smooth flow and reducing vortexing;
6) Bleed air regularly to prevent cavitation; drawn-in air accumulating over time causes cavitation, so venting preserves efficiency;
7) On commissioning, measure flow fluctuation ≤±5% (was ±20%); with stabilized flow the pulsation disappears, which verifies the fix;
8) Write the minimum level into the operating procedure; the field often lowered the level freely and caused vortexing, so operation now has a documented basis.

Checklist

Reference

GB/T 3766-2015 Hydraulic fluid power — General technical requirements