Knowledge Base › Fluid Systems Error Case › Water Emulsifying the Hydraulic Oil

Water Emulsifying the Hydraulic Oil

E44-669 · Hydraulic System Contamination and Stick-Slip · Hydraulic Oil · ★★

Problem Description

Emulsified oil, lubrication lost, water >500 ppm

Root Cause

[Mechanism] Water enters the oil and emulsifies it.
[Calculation] Water >500 ppm causes emulsification and loss of lubrication.
[Design Omission] No water sealing, no inspection, and no oil change were provided, leaving water.

Corrective Solution

1) Fit a desiccant breather (silica-gel desiccant, dew point ≤-20℃) to block humid air; because the tank breathes in moisture and water emulsifies the oil, breaking the emulsion destroys the lubricating film and raises wear, blocking moisture prevents emulsification;
2) Add a coalescing dewatering filter (capacity ≥10% of system flow, outlet water <100 ppm); because water and oil separate by coalescing on their density difference and removal restores the oil, dewatering recovers oil properties;
3) Test water content (Karl Fischer method, alarm >300 ppm); because water enters gradually invisibly and emulsifies above the threshold, early inspection gives warning;
4) Change to anti-emulsifying hydraulic oil (demulsification time ≤15 min, HLPD grade); because the original oil had poor demulsibility and emulsified easily, anti-emulsifying oil extends life;
5) Seal the cooler against leakage (water pressure < oil pressure by 0.05 MPa, leak check); because cooling water leaking into the oil emulsifies it, sealing blocks water;
6) Control condensation (tank insulation plus condensate drainage, temperature ≥5℃ above dew point); because condensation drips into the oil, control prevents it and reduces water;
7) Test oil quality on schedule (every quarter, visual condition plus water value); because emulsification builds up gradually and is quantified by inspection, oil is changed on the data;
8) Write water sealing and dewatering into the maintenance card (breather desiccant changed monthly); because the original lack of sealing is the root cause of water and fixing it closes the loop, maintenance enforces control.

Checklist

Reference

GB/T 11118.1-2011 Hydraulic oils