Knowledge Base › Fluid Systems Error Case › Particles in Oil Wearing the Pump

Particles in Oil Wearing the Pump

E44-668 · Hydraulic System Contamination and Stick-Slip · Hydraulic Pump · ★★

Problem Description

Pump wear, efficiency drop, abrasive particle wear

Root Cause

[Mechanism] Particles abrade the pump.
[Calculation] Particles cause wear and drop volumetric efficiency.
[Design Omission] No filtration, no oil change, and no inspection were provided, leaving particles.

Corrective Solution

1) Raise suction filtration accuracy to NAS 9 (β10 ≥75); because the original suction inlet had only an 80-mesh strainer and abrasive particles >10 μm entered the pump piston pair, dropping volumetric efficiency from 95% to 82%, fine filtration cuts particles, protects the pump, and restores efficiency;
2) Replace with a wear-resistant valve plate (Stellite hardfacing 0.8 mm thick); because wear on the porting face raises internal leakage and drops volumetric efficiency, hardfacing extends life;
3) Control system contamination to NAS 9 (online alarm when NAS >10); because contamination builds up invisibly and abrasion starts above the limit, threshold control gives early warning;
4) Add magnetic filters to remove iron swarf (magnetic field ≥0.4 T, trapping iron particles ≥25 μm); because iron swarf circulates and abrades the pump, magnetic capture removes it and protects the pump;
5) Count particles in oil samples on schedule (every 500 h); because gradual contamination is quantified by counting, which times the oil change, maintenance follows the data;
6) Shorten the oil-change interval to 2000 h; because long service accumulates abrasive particles that wear the pump, shorter changes keep the oil clean and control particles;
7) Clean the tank of settled sludge (magnetic plus manual cleaning, at every overhaul); because settled sludge recirculates and abrades, removing it cleans the oil at the source;
8) Write upgraded filtration and contamination control into the maintenance card (element change every 2000 h); because the original lack of filtration is the root cause of wear and fixing it closes the loop, maintenance enforces control.