Knowledge Base › Fluid Systems Error Case › Throttling Orifice Vortex Noise

Throttling Orifice Vortex Noise

E44-876 · Throttling Noise and Vibration · Throttling orifice · ★★

Problem Description

A large turning angle at the throttling orifice produced vortex noise of 87dB(A)

Root Cause

[Mechanism] The streamlines turn sharply at the throttling orifice, generating strong large-scale vortices that radiate noise.
[Calculation] Vortex scale l∝d; a large turning angle raises the turbulent kinetic energy, giving 87dB(A).
[Design Omission] No flow alignment, no guide vanes, no silencing.

Corrective Solution

1) Align the flow to cut vortices (use a streamlined throttling orifice to reduce the turning angle), since the original large turning angle gave vortex noise at 87dB(A), thus flow alignment cuts noise;
2) Verify the streamlines (turning angle ≤30° for a smooth transition), since disorder makes vortices and verification aligns the flow, thus verifying the streamlines;
3) Add guide vanes (a straightening grid ahead of the orifice), since disorder makes vortices and the grid evens them out, thus adding guide vanes;
4) Add a silencer (resistive, insertion loss ≥10dB), since the bare orifice radiates 87dB(A) and silencing lowers it, thus silencing;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the opening to steady it (moderate operation), since changing conditions make vortices and control steadies them, thus controlling the opening;
8) Write the flow alignment and guide vanes into the specification, since the original lack of alignment is the root cause of vortices and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL