Small pipe diameter over a long distance leaves the pump head insufficient

E44-108 · Excessive Piping Resistance & Pressure Drop · Plant water supply main DN80 · ★

Problem Symptom

DN80 was selected over 500m, giving v=2.8m/s above the design velocity, a friction loss of 0.42MPa and no water at the end of the line

Root Cause

[Pipe Diameter] The small diameter raises v and hf∝v².
[Calculation] hf=λL/d·v²/2g, and v=2.8 against 2.0 raises the resistance by 96%, so the head is insufficient.
[Design Omission] The diameter was not selected on the design velocity, so the head is insufficient.

Correct Solution

1) Re-select the pipe diameter for a design velocity of 1.5 to 2.0m/s, because a lower v reduces hf∝v², thereby making the head sufficient;
2) Re-select the pump head to match the new resistance, because changing the diameter changes the duty, thereby matching the operating point;
3) Install pressure measurement points along the line, because they reveal the loss distribution, thereby allowing verification;
4) Check the total hf against the pump head margin, because a margin must remain, thereby guaranteeing a steady supply;
5) Reduce the roughness of the inner wall to lower λ, because a lower λ gives a lower hf, thereby raising the pressure at the end;
6) Provide a booster pump where necessary, because the loss over a long distance is large, thereby making up the pressure;
7) Measure the end pressure during commissioning to confirm compliance, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the design velocity into the pipe sizing, because it must have a basis, thereby institutionalising the prevention of recurrence.

Checklist

References

GB/T 20801.3-2020 Pressure Piping Code - Design of Industrial Piping

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »