Uneven resistance in parallel branches causes flow imbalance

E44-107 · Excessive Piping Resistance & Pressure Drop · Parallel process branches · ★★

Problem Symptom

The two parallel branches had a resistance difference Δhf=0.05MPa, giving a flow ratio of 1.8:1, and the velocity in one branch was too high (3.2m/s) causing erosion

Root Cause

[Flow Imbalance] The branches have different length-to-diameter ratios, so their resistances differ.
[Calculation] Q∝√Δp, so the resistance difference produces a flow deviation of more than 30%.
[Design Omission] The branches were not laid out symmetrically and no balancing valves were fitted, so the flow was imbalanced.

Correct Solution

1) Lay out the branches symmetrically with equal length and diameter, because similar L/d gives similar resistance, thereby equalising the flow;
2) Fit a balancing valve on each branch to trim the resistance, because a common Δp can then be set, thereby holding the flow ratio at ≤1.1;
3) Use CFD to check that the branch resistance difference is ≤5%, because the imbalance originates in the resistance difference, thereby eliminating it at the design stage;
4) Fit a flow splitter at the inlet to equalise the pressure, because equal pressure gives equal flow, thereby reducing the imbalance;
5) Install flow metering on each branch, because it reveals the deviation, thereby allowing early adjustment;
6) Arrange the fittings symmetrically to reduce the difference in local loss, because differing ζ causes the imbalance, thereby distributing the flow evenly;
7) Measure the flow difference between the branches ≤10% during commissioning, because the design requirement must be verified by measurement, thereby closing out the acceptance;
8) Incorporate the balancing measures into the piping design, because it must be traceable, thereby institutionalising the prevention of recurrence.