E44-156 · Excessive Piping Resistance & Pressure Drop · 1200m long distance pipeline · ★★
The friction loss hf=λL/d·v²/2g=38m was not included, the pump head of 32m is insufficient and the flow at the end is only 60% of the design value
[Large Friction Loss] The long length L makes hf=38m, which exceeds the pump head.
[Flow Shortfall] The insufficient head lowers the pressure at the end and the flow is short.
[Design Omission] The total resistance was not calculated when the pump was selected, so the flow is short.
1) Calculate the total resistance with the Darcy formula hf=λL/d·v²/2g and select the pump head accordingly, because the 38m of friction loss over 1200m was omitted and left the head short, thereby calculating it fully and selecting the pump on that basis;
2) Increase the pipe diameter to reduce the velocity and hf, because a high v gives a large loss, thereby increasing the diameter to reduce the resistance;
3) Fit a booster pump at the end of the line to make up the head, because the trunk main head is insufficient, thereby boosting the pressure;
4) Check that the pressure at the most unfavourable point is at least the required value, because a low pressure at the end gives a flow shortfall, thereby checking the point and guaranteeing the flow;
5) Keep a piping resistance calculation sheet on file, because the original design omitted the calculation, thereby leaving a traceable record;
6) Measure the end flow against the design value during commissioning, because the design requirement must be verified by measurement, thereby closing out the acceptance;
7) Provide relief on the network to prevent overpressure, because the added head could otherwise exceed the limit, thereby relieving the excess pressure;
8) Make the total resistance check a mandatory item in the network design, because the omission of the calculation is the root cause of the flow shortfall, so the design must include it.
GB/T 20801-2020 Pressure Piping Code